Review of Environmental Factors - Camden Valley Way Upgrade and Liz Kernohan Drive Extension (Final) - Flipbook - Page 572
20
CAUTION - EXISTING SEWER
MAIN (375mm DICL) WITHIN
THE VICINITY OF WORKS
CT 59.76
60
ADJOINS SHEET 2
LIZ KERNOHAN DRIVE
MCA1
SCALE 1:500 @ A1
SCALE 1:1000 @ A3
0
5
10
20
30
40
Client
MDM
100% DETAIL DESIGN ISSUE FOR REVIEW
06.03.24
A
DRAFT ISSUE FOR REVIEW
01.08.23
MDM
TRC
Date
Drawn
Approved
Description
1cm at full size
10cm
CAMDEN COUNCIL
TRC
B
0
DBYD
GAS (DIGITISED)
REMOVE EXISTING UTILITY
NOTE: ALL UTILITIES DEPTHS TO BE CONFIRMED BY POTHOLING
CAUTION - EXISTING SEWER
MAIN (375mm MSCL) WITHIN
THE VICINITY OF WORKS
PROPOSED ELECTRICAL TO BE CONFIRMED
DESIGN SUBJECT TO SYDNEY WATER BPA
CAUTION - EXISTING SEWER MAIN
(500mm DICL - NOT SURVEYED)
WITHIN THE VICINITY OF WORKS
80
100
ADJOINS SHEET 6
NOT FOR CONSTRUCTION
North
-1
G
TC 127.23
50 metres
This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by:
Issue
COMMUNICATIONS (DIGITISED)
CAUTION - EXISTING WATER MAIN (250mm
CICL) WITHIN THE VICINITY OF WORKS
120
ADJOINS SHEET 6
DBYD
EXISTING UTILITIES TO BE REMOVED
CAUTION - EXISTING TELECOMMUNICATIONS
(18mm CABLE) WITHIN THE VICINITY OF WORKS
CAUTION - EXISTING SEWER MAIN
(375mm DICL - NOT SURVEYED)
WITHIN THE VICINITY OF WORKS
T
\NEWPROJ1ProjectsNSW21NSW210622DrawingsCADCIVDrawings20 CVW and LKD Consolidated PlansNSW210622-C112-10.dwg
CAUTION - EXISTING WATER MAIN
(250mm CICL) WITHIN THE
VICINITY OF WORKS
40.00
SEWER MAIN (DIGITISED)
20cm
70 CENTRAL AVENUE
ORAN PARK, NSW 2570
PHONE : (02) 4654 7777
FAX : (02) 4954 7829
© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.
ACOR Consultants Pty Ltd
Project
CAMDEN VALLEY WAY UPGRADE
BETWEEN HILDER STREET AND
T +61 2 4926 4811 KIRKHAM LANE INCLUDING
LIZ KERNOHAN DRIVE EXTENSION
The Forum, Level 1
Suite 1 240-244 Pacific Highway
Charlestown NSW 2290
Drawing Title
INTEGRATED UTILITIES PLAN
SHEET 3
Drawn
Date
JER
MAR 2023
Designed
Project No.
SP
Scale
1:500
A1
NSW210622
Q.A. Check
Date
TRC
28.02.24
Dwg. No.
Issue
C112-103
B
Mar 06, 2024 - 9:39am
TCS FOUNDATION DESIGN SUBJECT TO
SYDNEY WATER BPA
DBYD
ADJOINS SHEET 4
CAUTION - EXISTING
TELECOMMUNICATIONS CABLE
(18mm CABLE) WITHIN THE
VICINITY OF WORKS
ELECTRICAL COORDINATION SUBJECT
TO ISOLUX CONFIRMATION
S