Review of Environmental Factors - Camden Valley Way Upgrade and Liz Kernohan Drive Extension (Final) - Flipbook - Page 472
FOR TYPICAL RETAINING
WALL DETAILS REFER
DRG C110-201
℄ PIER
600
TOE OF WALL
6N12
TOP
0
100
200
400
600
800
500
500
Ø450
PIER
Ø600 STORMWATER
FRONT ELEVATION
RETAINING WALL No. STORMWATER LINE CROSSING
100
COVER TYP.
Ø450
PIER
PIERS TO BE FOUNDED
INTO STIFF CLAY OF
MIN. 250kPa BEARING
CAPACITY (TYP.)
SCALE 1:10 @ A1
SCALE 1:20 @ A3
1N16 'L' BAR CENTRAL
TYP.
300
MIN.
IL(TO BE CONFIRMED
ON SITE)
R10-300 TIES
IN PAIRS
105
APPROX.
6N16
BTM
6N12 TOP
300
RL -
R10-300 TIES
IN PAIRS
6N16 BTM
1400
1N16 'L' BAR
CENTRAL TYP.
PIPE IL
(VARIES)
Ø450
PIER BEYOND
Ø450
PIER
SECTION
SCALE 1:20
A
-
SCALE 1:20
1000mm
NOT FOR CONSTRUCTION
C COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved.
It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.
Client
This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by:
North
-1
MDM
100% DETAIL DESIGN ISSUE FOR REVIEW
06.03.24
A
DRAFT ISSUE FOR REVIEW
01.08.23
MDM
TRC
Date
Drawn
Approved
Description
0
1cm at full size
10cm
CAMDEN COUNCIL
TRC
B
Issue
\NEWPROJ1ProjectsNSW21NSW210622DrawingsCADCIVDrawings20 CVW and LKD Consolidated PlansNSW210622-C110-20.dwg
℄ PIER
20cm
70 CENTRAL AVENUE
ORAN PARK, NSW 2570
PHONE : (02) 4654 7777
FAX : (02) 4954 7829
ACOR Consultants Pty Ltd
Project
LIZ KERNOHAN DRIVE UPGRADE
BETWEEN CAMDEN VALLEY WAY
T +61 2 4926 4811
AND LODGES ROAD
Level 1, 54 Union Street
Cooks Hill, Newcastle NSW 2300
ENGINEERS MANAGERS INFRASTRUCTURE PLANNERS DEVELOPMENT CONSULTANTS
Drawing Title
RETAINING WALL NOTES AND DETAILS
SHEET 2
Drawn
Date
JER
MAR 2023
Designed
Project No.
SP
Scale
A1
AS SHOWN
NS210622
Q.A. Check
Date
TRC
28.02.24
Dwg. No.
Issue
C110-202
B
Mar 06, 2024 - 9:34am
600
TOE OF WALL RL(TO BE CONFIRMED
ON SITE)