Review of Environmental Factors - Camden Valley Way Upgrade and Liz Kernohan Drive Extension (Final) - Flipbook - Page 411
NOTES:
PITS AND LID SLABS TO BE CONSTRUCTED
FROM 40MPa CONCRETE WITH 40 COVER
U.N.O
2
PIPE SIZE - mm
900
1050
1200
1350
1500
-
PRECAST CONCRETE LINTEL
NOT SHOWN FOR CLARITY
℄ PIT ℄ OPENING AND LINTEL
OUTSIDE EDGE OF
FRAME TO BE FLUSH
WITH KERB LIP LINE
'X'
'X'
'
-
KERB LIP
LINE
'D
1
600
1/N16 OR 2/N12 TRIMMERS
150
TYP.
150
TYP.
1/N16 OR 2/N12 TRIMMERS ALL AROUND
'D' + 600 LONG
CRANK AS REQUIRED
TYPICAL TRIMMER BAR DETAIL AT PIPE
OPENING
TYPICAL OVERSIZED KERB
INLET PIT PLAN DETAIL
N.T.S
N.T.S
DETAIL ONLY REQUIRED WHERE DIMENSION 'X' EXCEEDS 300mm
FOR WALL REINF.
DETAILS REFER
SECTIONS
MIN DEPTH OF PIPE - mm
1800
1950
2100
2250
2400