LOCATION
Material
Finish
Brickwork with
Gloss
Colour
Dimension
Tile Finish
NOTE
Wall Tile Full Height
of Wall and to its
Full Extent
Epoxy Grout Not
Required
Ceiling
9 mm Fibre
Paint
Cement Sheet
Cornice
Square Edge
Paint
Expressed Joints
Shadowline is not
are not suitable
suitable
OPENINGS
TYPE
Door
Description
Finish
Hinged Solid
Paint
Colour
Core Timber
Dimension
NOTE
Minimum
Single Leaf swung
850 mm
in a direction to suit
Clear Width
Building
White Colours are
not suitable
Door Frame
Pressed Metal
Galvanised
Contrast
Frame
with Paint
to Door
r
r
r
Leaf
Window
Opening
Hardware
None
r
r
MLAK Keying Requirements. Access to the accessible area shall not allow access to
any other part of the building.
Confirm with Camden Council prior to commencement of works.
FITOUT
Specification of fitout items and installation of those items are all required to comply with AS1428.
TYPE
Fixtures
Description
Number
NOTE
Access Toilet
One
r
Connect Toilet to Service Duct.
In-Wall Panel Access to Toilet Services are not suitable.
Tap to Hand Basin
One
r
Any other Fixtures
As Required
r
Required in Accordance
with AS1428
PAGE 214